Operating Range |
Up to 20
Meters (65.6FT) off of a Red Hot glowing material ≤ 1200°C |
Supply Voltage |
-86
10 - 30 VDC
|
|
Power Consumption |
1 Watt
operating, 0.4 Watt in standby |
|
Typical
Accuracy |
± 6mm
(0.236in) |
Operating Temperature |
-10°C
(14°F) to +50°C (122°F) w/o air cooling |
|
-10°C
(14°F) to +60°C (140°F) with air cooling |
|
+2°C
to 65°C with (20°C/68°F) water cooling |
|
Resolution |
0.1mm user scalable |
Storage
Temperature |
-20°C
(-4°F) to +70°C (158°F) |
|
Repeatability |
± 2.0mm
(0.079in) |
|
Measuring Time |
160
msec. to 6 sec. (dependent on surface) |
Product Temp. Limit |
High Temp
≤ 1200°C
(2192°F) |
|
Update Rate |
5Hz |
Serial Interface (selectable)
|
RS232 or
RS422 (2400 - 38,400 baud)
|
|
Laser Wavelength |
650nm,
Visible Red |
Communication Protocol |
Half
Duplex via ASCII codes |
|
Laser Classification |
Safety
Class 2 (DIN EN 60825-1), Class
II |
Programming |
via
hyper-terminal and supplied software |
|
Laser Power |
1 mW |
Optional Interface* |
ProfiBus
DP gateway connection box, half duplex |
|
Laser Divergence |
0.6 mrad |
Auto Tracking |
Can be
programmed to start at power on |
|
Laser Spot Diameter |
6mm
(0.236in) at 10M (32.8ft)
12mm (0.472in) at 20M (65.6ft) |
Digital Output |
High value
output with adjustable threshold, logic and hysteresis. 0.5 A limit |
|
MTTF |
32,000 hrs |
Analog Output
|
Programmable 4-20mA, 16 BIT (0.15%) with 500 ohm distance limit.
|
|
Power Indication |
Red LED |
|
Trigger Input (optional) |
Adjustable
with delay & hi/lo adjustment
|
|
Temperature Drift |
< 50ppm/°C |