Working Range |
Natural
Surface |
0.5 - 20 M
(1.6 - 65.6FT) |
Hot
glowing material
≤
1400°C
(2552°F)
|
|
Relative Accuracy |
Repeatability1) |
+/- 5mm1) |
1 Sigma, N
infinite |
|
Laser Data |
Measurements per second |
1000 |
|
|
Measurements output |
up to 1 ms |
for N>1
moving average time higher |
|
Measuring Laser |
Safety
Class
I |
EN 60825-1:2001 |
|
Laser Divergence |
5 mrad |
Spot
Diameter (mm) = 20 mm + 5* x M |
|
Laser Wavelength |
905 nm |
|
|
Light Spot diameter |
4.5cm/7cm/12cm |
at
5M/10M/20M |
|
Red
Laser Pointer |
Safety
Class
II |
Operates
via serial interface |
|
Measuring Mode options |
Single
value, continuous & moving average |
standard |
|
Outputs |
Interface
(electrically isolated) |
RS232 or
RS422 |
Optional:
ProfiBus DP |
|
Analog (electrically isolated) |
4-20mA
(programmable) |
0.3%,
Start and Stop |
|
Digital (electrically isolated) |
Dual NPN
(programmable) |
Threshold,
direction and hysteresis |
|
Display |
4 LED's |
Status
function Display |
|
Power Supply |
18 - 30
VDC Isolated |
0.25A@24
VDC |
Electrically Isolated |
|
Environmental |
Enclosure
Protection Class
|
IP65
|
Aluminum
housing, 1.3kg
|
|
Shock & Vibration Rating |
IEC 68 |
|
|
Temperature Range |
Operational: -10 to +55°C
(14 to 131°F) |
Storage:
-25 to +70°C
(-13 to 158°F) |
|
Amplitude Control |
Mechanical |
Motorized
attenuation wedge |
error <5mm |