Model MLS
Laser Triangulation Measurement Meter
|
MLS
Laser Triangulation Measurement Meters
Laser
Triangulation & CCD array technique with digital signal processing
- Non-Contact Measurement of Distance,
Displacement, Thickness & Difference
- Works on almost any surface
- 2 High Temperature versions available
for Target Surface temperature of 1000°C, 1300°C or 1500°C
- Measurement ranges: 400 - 4000 mm.
(15.7 - 157.5 in.)
- Resolution: 0.01 mm to 0.5 mm
- Measurement frequency of 1000 Hz, 2000
Hz or 5000 Hz
- Robust Design
- Serial & Analog Outputs - Optional
Ethernet Now Available
- Synchronized thickness measurement with
two sensors
- Secondary Environmental Enclosure are
available including Air Purged, Air Cooled and Water Cooled with Air
Purging
|
|
Typical Applications |
-
Liquid Level
Control
-
Distance
measurement
-
Thickness
Measurement
-
Weight/Volume
Control
-
Constant
Tension Control
-
Roll Diameter
-
Profile
Measurement
|
-
Profile
Measurement
-
Control of
vacuum in containers
-
Control of Surface Treatments
-
Molten Metal Level
-
Vibration
Monitoring of a Rotating Object
-
Measurements
for quality control and statistics
-
Measurements
for feedback in productions lines
|
|
General Description
The MLS Laser Triangulation Meter (LTM) is a compact unit with
integrated optics and signal processor for precise measurement of
distance or product thickness and width. A focused laser spot is
illuminated on the object and the image distance determined by internal
CCD array. LED’s indicate when the object is at the center or is outside
of the measuring range. Installation software is provided for connection
to a PC and to display measured values. Measurement of data is via RS232
and analog outputs.
The MLS models operate at a measuring and serial output update
frequencies of 1,000 measurements per second. All MLS models have
programming/select functionality. The main feature is Group Mode. In
Group Mode a running average is calculated over a user specified number
of measuring points. The user also programs the meter to disregard a
number of, usually all (if there are any zero measurement results),
before calculating the average value. The average values are calculated
at full measuring frequency and are used for converting the analog
signals.
Two identical MLS LTM’s when connected together automatically provide
change in thickness, width or difference values. The MLS Standard models
operate at a 1kHz measuring & update frequency and have a serial
interface baud rate of 38400. Optional -S2 models operate at a 2kHz
measuring frequency and at a 1kHz or 2kHz update frequency, and have a
serial interface baud rate of 38400 or 115200. Optional -S5 models
operate at a 5kHz measuring frequency, and at a 1kHz, 2½kHz or 5 kHz
update frequency and have a serial interface baud rate of 38400, 115200
or 230400. The baud rate of 230400 requires option -R4 RS422/RS485
serial Interface.
The MLS laser triangulation meters have a broad range of usage for
measurement off surfaces where other devices fail. Ideal for measuring
off wood, plastic, glass, rubber, paper, foam, textiles, food product,
cold, hot or molten metals as well as various liquids. |
|
Performance Information
MLS Models
|
Model |
MLS500 |
MLS505 |
MLS700 |
MLS925 |
MLS1100 |
MLS1150 |
MLS1400 |
MLS1950 |
MLS3000 |
|
Measured range (mm) |
400
- 600 |
450
- 550 |
600
- 800 |
600
- 1250 |
1000
- 1200 |
700
- 1600 |
700
- 2100 |
1500
- 2400 |
2000
- 4000 |
|
Center distance (mm) |
500 |
500 |
700 |
925 |
1100 |
1150 |
1400 |
1950 |
3000 |
|
Resolution |
<0.05 mm |
0.01 mm |
<0.05 mm |
<0.1 mm |
<0.05 mm |
0.1 mm |
<0.3 mm |
0.2 mm |
<0.5 mm |
|
Reproducibility |
±0.05 mm |
±0.01 mm |
±0.05 mm |
±0.1 mm |
±0.05 mm |
±0.1 mm |
±0.3 mm |
±0.2 mm |
±0.5 mm |
|
Linearity (of Full Scale) |
±0.1 mm |
±0.05 mm |
±0.01 mm |
±0.3 mm |
±0.1 mm |
±0.4 mm |
±0.7 mm |
±0.5 mm |
±1.0 mm |
|
Laser Spot Size |
Ø 2 mm |
Ø 1 mm |
Ø 2 mm |
Ø 4 mm |
Ø 3 mm |
Ø 4 mm |
Ø 5 mm |
Ø 5 mm |
Ø 5 mm |
|
|
|
|
|
Click Here for Additional information on MLS Laser
Triangulation Meters. |
|
|
|
|
|
|
|
|