Moduloc Control Systems Sensors & Systems  For Control, Measurement & Management for Process Automation. Moduloc Control Systems Industrial Sensors & Systems for Control, Measurement & Management for Mill & Process Automation.
ODS Laser Triangulation Measurement Meters Technical Data


ODs laser Triangulation Measurement Meters for precise Laser Measurement
 
Type C - Compact Model
Model ODS250
Laser Triangulation Measurement Meter

Type S - Standard Model
Model ODS1950
Laser Triangulation Measurement Meter

 

Performance Information

Type C - Compact Models

Model

ODS20.5

ODS115

ODS150

ODS200

ODS250

ODS450

ODS750

Measured range (mm)

16-25

110 - 130

100 - 200

100 - 300

100 - 400

200 - 700

400 - 1100

Center distance (mm)

20.5

115

150

200

250

450

750

Resolution

0.0008 mm

0.002 mm

0.010 mm

0.05 mm

0.08 mm

0.1mm

0.5 mm

Reproducibility

±0.0008 mm

±0.002 mm

±0.010 mm

±0.05 mm

±0.08 mm

±0.1mm

±0.5 mm

Linearity (of Full Scale)

±0.05%

±0.1%

±0.05%

±0.1%

±0.1%

±0.05%

±0.1%

Select-1 Option

N/A

N/A

N/A

Included

Included

Included

Included

Select-2 Option

Available1

Available1

Available1

Available

Available

Available

Available

-HT Option

N/A

Available

Available

Available

Available

Available

Available

Size of Spot

Ø 0.1 mm

Ø 1 mm

Ø 1 mm

Ø 2 mm

Ø 2 mm

Ø 2 mm

Ø 4 mm

 

Type S - Standard Models

Model

ODS 500

ODS 505

ODS 700

ODS 925

ODS 1100

ODS 1150

ODS 1400

ODS 1950

ODS 3000

Measured range (mm)

400 - 600

600 - 800

600 - 800

600 - 1250

1000 - 1200

700 - 1600

700 - 2100

1500 - 2400

2000 - 4000

Center distance (mm)

500

500

700

925

1100

1150

1400

1950

3000

Resolution

<0.05 mm

0.01 mm

<0.05 mm

<0.1 mm

<0.05 mm

0.1 mm

<0.3 mm

0.2 mm

<0.5 mm

Reproducibility

±0.05mm

±0.01mm

±0.05mm

±0.1mm

±0.05mm

±0.1mm

±0.3mm

±0.2mm

±0.5mm

Linearity (of Full Scale)

±0.05%

±0.05%

±0.05%

<±0.05%

±0.05%

<±0.05%

<±0.05%

<±0.05%

<±0.05%

Select-1 Option

Included

Included

Included

Included

Included

Included

Included

Included

Included

Select-2 Option

Available

Available

Available

Available

Available

Available

Available

Available

Available

-HT Option

Available

Available

Available

Available

Available

Available

Available

Available

Available

Size of Spot

Ø 2 mm

Ø 1 mm

Ø 2 mm

Ø 4 mm

Ø 3 mm

Ø 4 mm

Ø 5 mm

Ø 5 mm

Ø 5 mm

 

Serial Output

RS232 Standard - up to 38400 baud

Supply Voltage

24VDC ±10%

Serial Output

RS422/485 (optional)

Power Consumption

4.5 Watt

Digital Output

Digital output 1/10 values of full range

Humidity

Max 90% RH (non condensing)

Analog Output

1-9VDC/4-20mA

Operating Temperature

0°C to +45°C

Updating Frequency

500/1000 Hz (1000/2000 Select-2 Models)

Storage Temperature

-20°C to +70°C

Temperature Deviation

±0.03% of F.S./°C

Product Temp. Limit

Standard 600°C/Hi-Temperature 1200°C

Light Source

Visible 670 nm Laser

Laser Class

IEC 2

General Specifications

Serial Interface

RS232 Standard - up to 38400 baud

Supply Voltage

24VDC ±10%

Optional Serial Interface

RS422/485

Power Consumption

4.5 Watt

Digital Output

Digital output 1/10 values of full range

Humidity

Max 90% RH (non condensing)

Analog Output

1-9VDC/4-20mA

Operating Temperature

0°C to +45°C

Updating Frequency

500/1000 Hz

Storage Temperature

-20°C to +70°C

Temperature Deviation

±0.03% of FS/°C

Product Temp. Limit

Standard 600°C

Light Source

Visible Red 670 nm Laser

Laser Class

IEC 2

 

Select-1 Version

Eleven of the thirteen ODS Laser Triangulation Meter models are provided as standard as programmable Select-1  versions .

Theses ODS Select-1 Laser Triangulation Meter are programmed with the PC software supplied with the sensor. The PC Program receives data from the ODS Select-1 Laser Triangulation Meter and displays the  measured distance on the PC screen. When the ODS Select-1 Laser Triangulation Meter is specifically  hardwired the PC program is able to send data to the Meter. The sent instructions given are stored in the Meter's flash memory and are retained until the Meter is reprogrammed.

The Select-1 version can be operated in 4 modes of operation

  • Group mode - offering averaging after filtering out zero values.
  • Stop & Go - measuring activity via RS232.
  • Level mode - In this mode the measured output distance reading is reversed.
  • Extended thickness mode - In this mode the measuring range is doubled at half the resolution.

In Group mode the user can define a number of consecutive measurements to be a Group of values. The ODS Laser Triangulation Meter in this Mode is able to update the Group with a new measurement result at 1 kHz and output the Group average at the same rate. Furthermore the user can instruct the ODS Laser Triangulation Meter to disregard up to a certain number of void measurements with null-values in the Group, and have the output calculated as the average of the remaining values in the Group.

 

Select-2 Version

The optional Select-2 is the high performance version of the ODS Laser Triangulation Meter. The Select-2 version offers the benefits of increased measuring performance by run time programmability on:

  • Moving targets
  • Angled surfaces
  • Colorful surfaces
  • Shiny/difficult surfaces
  • Transparent surfaces

The Select-2 version obtain higher performance compared to the Standard models by:

  • Operating at twice the measuring and output frequency with a
  • Maximum Baud Rate of 11520
  • Utilizing mathematically optimized intensity control of the laser light
  • Offering elimination of light penetrating into partly transparent surfaces
 
-HT High Temperature

All ODS Laser Triangulation Meter are available with the  -HT option. The
ODS Laser Triangulation Meters with this option are designed for target surfaces with high temperatures up to 1200°C. The ODS -HT Meters are especially useful for use on very hot objects such as hot rolled steel or molten metals. The ODS -HT Meters are like other ODS Meters and designed to give good measuring accuracy over a large measuring range.
 

Laser Thickness Measurement  -  All ODS Laser Triangulation Meters will automatically transform into either the Master or the Slave of a two Laser Triangulation Meter Thickness Measuring System when connected to an identical ODS Laser Triangulation Meter.

Laser Thickness Measurement
All ODS Laser Triangulation Meters when connected to an identical(**) ODS model will automatically transform into the Master or the Slave of a two Laser Triangulation Meter Synchronized Thickness Measurement System.

The Master ODS Laser Triangulation Meter reads the digital distance data sent from the Slave ODS Laser Triangulation Meter over the RS232 serial interface. After taking its own distance information into account, the Master Laser Triangulation Meter will output the change in thickness to the serial interface as well as to the analog output.

The Laser Triangulation Meter are synchronized and will measure on semitransparent targets if they are wired to run at half the measuring frequency.

Thus a pair of ODS Laser Triangulation Meters will  measure thickness, width or difference without any control box or special calibration from the factory.

This unique characteristic of the ODS Laser Triangulation Meters are available in the Select-1 version as well as in the Select-2 and -HT High Temperature Models.

(**)= ODS500, ODS505, ODS700, ODS900 and ODS1000 have the unique capability of connecting to any other ODS model to form a Master - Slave Synchronized Thickness Measuring System.

 

Dimensional Information  
Type C - Compact Models

Housing: Steel/Aluminum/Glass
Housing Rating:
IEC IP65
Weight w/o Cable:
1.6 Kg
Cable Length:
2.5 M

ODs laser Triangulation Measurement Meters for precise Laser Measurement

 
Dimensional Information

Type C - Standard Models

Housing: Steel/Aluminum/Glass
Housing Rating:
IEC IP65
Weight w/o Cable:
3.6 Kg
Cable Length:
2.5 M

ODs laser Triangulation Measurement Meters for precise Laser Measurement

 

TM65-WP Water Cooled & Air Purged LTM Enclosure

Housing: 316 Stainless Steel
Housing Rating:
IEC IP65

 

Model MLS1950
Laser Triangulation Measurement Meter mounted in a
TM65-WP water cooled and air purged enclosure

 

MODULOC® Technology - The Total Laser Solution

 
Would You like additional information? Click here for our Request for Information Page.
OR

Click Here to Download a printable
ODS Laser Triangulation
Measurement Meter Brochure.

 

 

 

• Up •