Laser Thickness Measurement
All MLC, MLM & MLS Laser Triangulation Sensors will automatically transform into
either the Master or the Slave of a two Laser Triangulation Sensor
Thickness Measuring System when connected to an identical MLC, MLM
or MLS Laser Triangulation Sensor.
The Master Laser Triangulation Sensor reads the digital distance
data sent from the Slave Laser Triangulation Sensor over the RS232
(or optional RS422) serial interface. After taking its own distance
information into account, the Master Laser Triangulation Sensor will
output the change in thickness in its calculated digital form as
well as a converted analog signal. The Laser Triangulation Sensors
are synchronized. They will measure on semitransparent targets
if they are wired to run at half the measuring frequency.
A pair of MLC, MLM or MLS Laser Triangulation Sensors will thus measure
thickness, width or difference without any control box or special
calibration from the factory. |
|
|
Typical Applications |
- Ideal for precise and accurate Laser
Measurement Applications
- Laser Thickness Measurement
- Laser Thickness Measurement of metal/steel
bar, plate, slab and strip.
- Laser Thickness Measurement of any flat
product including plastic, film, glass, wallboard, wood, etc.
- Laser Width Measurement
- Laser Width Measurement of metal/steel bars,
billets, plates, slabs, etc.
- Laser Width Measurement of any product
including plastic, wallboard, wood, etc.
- Laser Length Measurement.
Laser Length Measurement of metal/steel bars, billets, plates, slabs,
etc.
- Laser Length Measurement of any product
including plastic, wallboard, wood, etc.
- Profile Measurement.
- Laser Thickness Measurement Gauge
- Strip Thickness Measurement Gauge
|
|
MLC,
MLM &
MLS
Laser Triangulation Measurement Sensors
Laser
Triangulation & CCD array technique with digital signal processing
- Precise Laser Distance Measurement by
triangulation
- MLC,
MLM & MLS product family includes twenty-one
models.
-
Measuring ranges: 16mm
(0.63")
to 4M
(13 Feet)
- Resolution
& Reproducibility:
0.0008mm to 0.5mm
- Serial
Interface
& Analog Output
-
Two High Temperature Models
are available that can be used with hot metal up to
900°C (1652°F) and up to
1500°C (2732°F).
-
Secondary Environmental Enclosure are
available for additional protection including Air Purged, Air Cooled
with Air Purging and Water Cooled with Air
Purging
|