Typical Detection |
10mm Rod at 350°C from 2 meters and 50mm Bar at 350°C from 4 meters. |
Remote Self Check |
Remotely Energized - Continuous Test |
|
Sensing Elements |
Electronically Scanned InGaAs Diodes |
Continuous Self Check |
Opto-isolated Outputs (+) & (–) |
|
Scan Rate |
1,200 Scans/Sec. |
Operating Temperature |
-20°C (-4°F) to +50°C (122°F) without air or water cooling |
|
Min Product Temp. |
250°C |
-20°C (-4°F) to +60°C (140°F) with air cooling |
|
Product Position Display |
10 LED Array Bar Display |
-20°C (-4°F) to +90°C (194°F) inline vortex air cooling |
|
Scanning Angle: |
Standard: 1° x 15°
Optional: 2° x 22°, 3° x 35° |
+2°C
(36°F) to +120°C (250°F) with water cooling |
|
Detection Technique |
Differential comparison between background and hot product. |
Output (1) |
Reed Relay Output (N/O) 240 VAC, 1A, 20W - 4 msec. response |
|
Response Time: |
1- 250 msec. digitally adjusted locking timers |
Output (2) |
Opto-isolated NPN Output 300 V, 150 mA, 200mW - 2 msec. response |
|
Supply Voltage |
110 VAC ± 15% 50/60 Hz and 24 VDC +10%, -15% |
Output (3) |
NPN & PNP Outputs 400 mA, 45 V, 2A peak with 24 VDC connection |
|
Power Consumption |
5 VA |
|
|